<< Click to display table of contents >> Navigation: TiCon Base > MTM, MTM-1 and MTM-2 Analysis > MTM-1® analysis |
For the elements of the MTM-1® analysis element configuration, the same allgemeinen Tabs are available as in all other element types.
Evaluation according to Ablaufindikatoren is also implemented.
The resolution of structures in the tree view is not supported.
MTM-1® analyses are printed with the help of the Standard-Druckmöglichkeiten.
Note: |
MTM-1® analyses can be created on the basis of metrical or non-metrical ("imperial") measuring units. The latter are especially used in the United States, where units such as "inches" are used. This results in different times for identical codes for the MTM-1® values based on the lengths of motion. |
Example: Code R6B
Unit |
Distance |
Time |
metric |
6 cm |
4.5 TMU |
imperial |
6 Inch (15.2 cm) |
8.6 TMU |
The corresponding settings have to be made in the TiCon Administration for the MTM-1® analysis [A1] element configuration.