<< Click to display table of contents >> Navigation: TiCon HWD > MTM-HWD Analysis > MTM-HWD Assembly > Balancing difference |
In the "Balancing difference" tab, select the posture that is taken during the balancing compensation time. The posture is taken into account in the EAWS® evaluation. The "Balancing difference" tab is only available for an HWD® assembly (structural behavior: HWD® assembly).
Example on how to proceed:

The workplace organization tab with a set cycle time of 120 s

Element structure with a total time of 90.94 s
The defined cycle time of the workplace organization and the time defined in the structure result in a balancing compensation time of 29.1 s (120 s – 90.94 s). Since HWD® always assumes a cycle time of 100%, an ergonomic evaluation is carried out for the balancing compensation time. The posture taken for the evaluation is defined in the "Balancing difference" tab.

Balancing difference tab for adjusting the posture that is present during the balancing compensation time.

EAWS® evaluation with a balancing compensation time of 29.1 s